Support Articles
There are several versions of the aPower X LEDs depending on the version of your device. If you do not know the version of your current LEDs, please consult with your installer.
The following explains the LED status for various versions when the aPower X is charging, discharging, malfunctioning and shut off. LEDs are lit from bottom to top as there is higher stored charge. For example, when 20%≤SOC<40%, only the first LED is on.
· Charging:
The LEDs are lit up to current charge and the next higher LED is flashing.
A flowing (up to down) animation is displayed.
· Discharging: The LEDs indicate the SOC level.
· Standby:
The LEDs display current SOC.
LED strips 1~5# flash together in a 5s cycle.
· Malfunctioning: LED strips 1~5# flash together in a 1s cycle
· Shutdown: The LED indicators corresponding to the SOC level are normally on, when FHP is shut down in on-grid mode. All LEDs are turned off when the FHP is shut down in off-grid mode.